Summary

Yüksek gerilim sistemlerinde meydana gelen elektromanyetik alan, adından da anlaşılacağı gibi, elektrik alan ve manyetik alan olmak üzere iki bileşenden meydana gelmektedir. Bu çalışmada, yüksek gerilim güç sisteminde kullanılan bir iletim hattının hem normal koşullardaki hem de varsayımsal durumlardaki farklı zamanlardaki elektrik analizi ayrı ayrı gerçekleştirilmiştir. Analiz edilen iletim hattı, 380 kV, 3-faz ve 50 Hz frekanstaki alternatif akım değerler göz önünde bulundurularak analiz edilmiştir. Her faz için kullanılan iletkenler 32,1 mm çapındaki iki iletkenden meydana gelmektedir. Ayrıca iletim direğinin tepesinde her biri 24,01 mm çapında iki topraklama kablosu ve koruma hattı bulunmaktadır. İncelenen kısım, kulenin merkezinden (X ekseninde) her taraf için 32 m ve yerden (Y ekseninde) 540 m yükseklik dikkate alınarak, iletkenlerin uzunluğuna dik bir alanı kapsamaktadır. Bu çalışmada, modelleme ve elektrik alan analizi ANSYS@Maxwell simülasyon aracı kullanılarak gerçekleştirilmiştir. Model üzerinde meydana gelen elektrik alan dağılımı ve şiddeti elde edilmiştir.



Keywords
Yüksek gerilim, Elektrik alan, ANSYS@Maxwell, İletim hattı.

Abstract

The electromagnetic field that occurs in high voltage systems, as the name suggests, consists of two components, electric field, and magnetic field. In this study, the electrical analysis of a transmission line used in a high voltage power system at different times in both normal conditions and hypothetical situations was carried out separately. The analyzed transmission line has been analyzed considering the alternating current values at 380 kV, 3-phase, and 50 Hz frequencies. The conductors used for each phase consist of two conductors with a diameter of 32.1 mm. In addition, there are two earthing cables and a protection line, each 24.01 mm in diameter, at the top of the transmission pole. The section under study covers an area perpendicular to the length of the conductors, taking into account the height of 32 m for each side from the center of the tower (on the X-axis) and 40 m from the ground (on the Y-axis). In this study, modeling and electric field analysis were carried out using ANSYS @ Maxwell simulation tool. The electric field distribution and intensity on the model have been obtained.



Keywords
High voltage, Electric field, ANSYS @ Maxwell, Transmission line.

Advanced Search


Announcements

    ARALIK Sayısı

    VERBİS'E KAYIT S�RELERİ HAKKINDA DUYURU | Kırklareli Ticaret ve ...

    ARALIK ayında yayınlanacak Sayımız için  20 KASIMTarihine kadar çalişmanızı Yükleyebilirsiniz



Address :Kazakh National Women's Pedagogical University, Almatı, Kazakhistan
Telephone :+7 778 921 0336 - 0 534 349 92 73 Fax :
Email :ejonsjournal@gmail.com

Web Yazılım & Programlama Han Yazılım Bilişim Hizmetleri